|
Past Performance for Converged Dynamics
VAMC ABQ
Contact:
Fred W. Dove
Telecom/OI&T
1501 San Pedro Drive SE
Albuquerque, NM 87108-5154
(505) 265-1711 x6438
Scope:
From the period of June of 1998 until present DCI has provided
the following services to the VAMC ABQ. VAMC ABQ operates a Nortel
Option 81C Meridian 25.40 PBX with 16 Port meridian Mail and (2)
networked Opt11C systems connected to this switch. These systems
serve a total of 2150 users.
·
PBX Equipment Installation Services
·
PBX Maintenance Services
·
On-Site PBX Moves, Adds, and Changes Support
·
Consulting and Engineering for PBX Design and problem solving
·
24X7 Technical Support for system critical outages
·
Cabling Services Inside – CAT5E, CAT6, Fiber Optic
·
Cabling Services Outside Plant – Campus Cabling Copper and
Fiber Optic
Internal Revenue
Service – Albuquerque
Contact:
Juanita Rains
5338 Montgomery Blvd NE
Albuquerque, NM 87109
Scope:
Cabling:
16 Dual CAT5e voice/data cable drop
1 Installation of above including physical installation,
termination, testing and labeling
1 Removal of [17] existing cables not currently in use
Internal Revenue
Service –
Seattle Territory – Farmington, NM
Contact:
Juanita Rains
800 E. 30th Street
Farmington, NM 87499
Scope:
Provide turn-key communications.
New voice and data cable runs.
6 data and 6 Voice CAT 5E, 568A, 4 pair, 24 awg. plenum rated cable
runs (75ft or less) from rack mounted patch panel terminated into
dual voice/data RJ-45 -110 wall jacks or workstations. Label and
Test.
Sun Healthcare ABQ
Contact:
Gerry Stone
Sun Healthcare Group
MIS Telecom Engineer
505-468-6688
505-468-8239 fax
Gerry.Stone@sunh.com
Scope:
From the period of December 2003 until present DCI has provided
the following services to the Sun Healthcare ABQ. Sun Healthcare
operates a Nortel Option 81C Succession 4.5 PBX with AVST Call
Express Voice Mail. They have a networked BCM and a networked Opt11C
connected to this switch. These systems serve a total of 700 users.
·
PBX Equipment Installation Services
·
PBX Maintenance Services
·
On-Site PBX Moves, Adds, and Changes Support
·
Consulting and Engineering for PBX Design and problem solving
·
24X7 Technical Support for system critical outages
·
Cabling Services Inside – CAT5E, CAT6, Fiber Optic
·
Cabling Services Outside Plant – Campus Cabling Copper and
Fiber Optic
Boeing SVS Engineering ABQ
Contact:
Chuck O'Donnell
System Administrator
Boeing-SVS, Inc.
505-449-4685 DID
505-463-7443 PCS
chuck.p.odonnell@boeing.com
Scope:
From the period of March 1999 until present DCI has provided the
following services to the Boeing SVS Engineering ABQ. Boeing SVS
operates a Nortel Option 11C Succession 4.5 PBX with 12 Port
Meridian Mail. This system serves a total of 400 users.
·
PBX Equipment Installation Services
·
PBX Maintenance Services
·
On-Site PBX Moves, Adds, and Changes Support
·
Consulting and Engineering for PBX Design and problem solving
·
24X7 Technical Support for system critical outages
·
Cabling Services Inside – CAT5E, CAT6, Fiber Optic
·
Cabling Services Outside Plant – Campus Cabling Copper and
Fiber Optic
·
Wide Area Network Support for Routing and Switching Equipment
ATK Mission Research ABQ
Contact:
Linda McCormick
Office Manager
505-768-7606 DID
Linda.McCormick@ATK.COM
Scope:
From the period of May 1999 until present DCI has provided the
following services to the ATK Mission Research ABQ. Mission Research
operates a Nortel Option 11C Rls 25.40 PBX with 12 Port Meridian
Mail. This system serves a total of 300 users.
·
PBX Equipment Installation Services
·
PBX Maintenance Services
·
Consulting and Engineering for PBX Design and problem solving
·
24X7 Technical Support for system critical outages
·
Cabling Services Inside – CAT5E, CAT6, Fiber Optic
·
Cabling Services Outside Plant – Campus Cabling Copper and
Fiber Optic
·
Wide Area Network Support for Routing and Switching Equipment
Dekker,
Perrich, Sabatini Architects
Application
and Solution:
Toshiba IP
PBX - Toshiba
CIX670 System with 12 Port Stratagy Voice Mail System.
Station
Cabling - DCI will
install (192) Dual CAT5e drops, (25) Single CAT5e drops, and
(12) Single CAT5e WAP drops at locations [as marked on
plans] on the second floor to be terminated in the first floor
server room. (6) 4” conduits will be furnished by DPSA for DCI to
use to distribute cables from the 2nd floor to the 1st
floor server room. DCI will also install (27) Dual CAT5e
drops, (8) Single CAT5e drops at locations [as marked on
plans] on the first floor to be terminated in the same first floor
server room. All cables will be installed under the raised floor,
being attached to the floor support system with plenum rated ties.
Penetrations will be furnished by the flooring contractor for access
to modular furniture. Blue and orange patch cords will be provided
by DCI for the system end termination point in 3 and 5 foot lengths.
Paging -
DCI will install (12)
ceiling speakers, (1) 2 amp power supply, and associated cabling on
the second floor.
Feed
Cabling - DCI will
install a 25pr cable from the building demarcation point to the
first floor server room. Both ends of this cable will be terminated
on wall mounted 110 blocks.
Server Room
- DCI will install (2)
84” 2 post relay racks with vertical and horizontal management to
facilitate the (11) 48 port patch panels [station cables], PBX tail
terminations, switches, etc. (2) 84” 4 post server racks will also
be installed to facilitate DPSA’s servers and DCI provided UPS’s,
KVM switch/monitor, rack mount power strips, etc. (1) HP ProCurve
4160gl bundle will also be provided and installed by DCI personnel.
Converged Dynamics - About Us
Converged Dynamics - Line Card
Converged Dynamics - Contact Us
|